Surgical Lighting

For major and minor surgery and as an examination lamp in:

Operating rooms
Out-/Inpatients
Emergency Wards
Examination rooms
Veterinary practices

Versatile and compact design
Air stream optimised for laminar-flow compatibility
Light and flexible for easy positioning
Removable, sterilsable handles
Easy replacement of Halogen/Xenon bulbs
Uniform illumination across working area
Colour correction for visual comfort
Shadow-free in operation field
Very sturdy construction
Hermetically sealed

High performance
High lux output/intensity
Deep cavity penetration
Sharply focused, high intensity light pattern
Heat reflected upwards and transmitted through the IR-transmitter
Dimmable lights
High lux up to 4 x 150,000 lux

click picture to enlarge

 
 
The comprehensive Admeco-Lux program

Ceiling
Individual lights 2 beams 1-branch, “SOLO”, not focusable
Individual lights 3-6 beams, 1-branch, “SOLO”, focusable
Ceiling hanging surgical lights, 2-branches “DUO”, focusable
Ceiling hanging surgical lights max 4-branches “MULTI” focusable





Wall
Individual lights 2 beams, not focusable
Individual lights 3-6 beams, focusable










Mobile
Individual lights 1-2 beams, not focusable
Individual lights 3-5 beams, focusable
Optional with emergency power supply (as in picture)

click pictures to enlarge

click pictures to enlarge

 
 
Admeco-Lux 6SI in detail

IR-Transmitter
Because of the infrared permable hood of the lamp most of the heat is exhausted upwards. The result is a cooler working field for the surgeons.

Diameter
The Admeco-Lux is specially designed for laminar-flow outlets. The very small diameter of only 8 cm and the stream optimised shape of the light heads are disturbing the airflow to a minimum.

Focus- / Positioning
The lamp can be positioneAd and focused fast and easily with the swivelling sterilisable handle.










Easily maneuverable with two centre-close joints
The rotation points A and B of the Admeco-Lux OT-lights are close to the centre. This creates an extreme mobility almost comparable with a ball-joint. With fingertip light manipulation Admeco-Lux lamps can be positioned in the appropriate angle.

click pictures to enlarge

click pictures to enlarge

 
 

 

Enlightening Design

• Innovative

• High Quality

• High Performance

 
 
 
Airborne particle concentration control for a operating room
Authors: Air & Climate Group, Dr Dipl.-lng. ETH Alfred Moser, Dr Yunlong Liu, ETH Zurich

“The standard case is from a real situation except that persons around the table are represented by dummies. The 6-lamp light and the big light are placed in the same position, the big light is a dish-shaped light with a diameter of about 0.9m (CFD*1), the
6-lamp light is made up of 6 0.08m-diameter small lamps (CFD*2)”



“The large lamp will disturb the flow field so much that the particle concentration above the table is seriously affected CFD 1 shows the airflow vectors in the centre of the table. It is obvious that this large lamp is not suitable to be placed between air supply inlet and the operating table
 
 
Surgical Light with colour video system

The system includes?

Colour video camera integrated into a casing which can be attached to an Admeco-Lux surgical light or a separate arm (Admeco-Lux models 3SI, 4SI and 5SI).

Control unit includes interference filter


Colour video camera
The colour video system designed to accompany the ADMECO-Lux surgical lights needs no additional , visible cables.
The system is optically integrated into the light design. The video camera is built into a casing which is then fastened to the Admeco-Lux surgical light or to an independent arm.
By means of the sterisable handle, the camera can be turned within the casing and the image positioned corrected as necessary
The system is simple to install and easy to maintain.

Control unit including interference filter
The control unit of the colour video camera allows you to adjust the iris, zoom, focus
and white balance.
A green LED by the auto-iris, auto-focus or white balance buttons lights up when the function is activated.
   
Colour video system technical data
Camera 1/4” CCD-Chip. Sony (10x zoom)
Scanning rate 2:1
Pixel 752 (H) x 582 (V)
Horizontal frequency 15652 Hz
Image frequency 50 Hz
Auto shutter 1/3 - 1/10,000 s; 20 steps
Minimum light 4 lux
Fuse (electronic) 400mAT (230V)
Focusing range zoom lens 4.2 to 42mm
White balance Automatic
Fitting in a casing suitable for the ADMECOLux surgical light

Control unit technical data
TV standard
PAL (alternatively NTSC)
Resolution >460 (H) TV Lines x > 400 (V);
TV Lines
Signal output FBAS, Y/C (S-VHS, Hi8)
Video output Yes
Power supply 230V, 50-60 Hz
Humidity <90% rF
Ambient temperature 0 deg C to +50 deg C
(Right to change specifications reserved)

 

click pictures to enlarge

 

 

 
 
Technical Data

criteria / model
6SI
5SI
4SI
3SI
Illumination intensity at 1 metre in lux
= 150,000
= 125,000
= 100,000
= 75,000
Field size at 1 metre in cm (inches)
18 - 27
(7.1 - 10.6)
18 - 27
(7.1 - 10.6)
18 - 27
(7.1 - 10.6)
18 - 27
(7.1 - 10.6)
Colour temperature (K)
~4,300K
+ or - 300K
~4,300K
+ or - 300K
~ 4300K
+ or - 300K
~4300K
+ or - 300K
Working distance in cm (inches)
70 - 200
(27 - 79)
70 - 200
(27 - 79)
70 - 200
(27 - 79)
70 - 200
(27 - 79)
Colour rendering index
93
93
93
93
Focal length in cm (inches)
60 (23.6)
60 (23.6)
60 (23.6)
60 (23.6)
Temperature increase in wound area at 100,000 lux and 1 metre in deg C (F)
10 (50)
10 (50)
10 (50)
10 (50)
Focus adjustable by sterilisable handle
Yes
Yes
Yes
Yes
Easy positioning by sterilisable handle
Yes
Yes
Yes
Yes
Dimmer with continuos light regulation
Yes
Yes
Yes
Yes
Support
cardanic
cardanic
cardanic
cardanic
Number of light heads and bulbs for each model
6
5
4
3
Electric power (Watt)
300
250
200
150
Diameter of one beam in cm (inches)
8 (3.1)
8 (3.1)
8 (3.1)
8 (3.1)
Diameter of light heads circle in cm (inches)
(External-diameter of the surgical light)
40 (15.7)
40 (15.7)
39 (15.4)
39 (15.4)
Flow obstructing surface in cm2
380
330
280
230
Laminar-flow index (Leenemann)
5.2
4.6
4
3.4 (7.5)
Weight in Kg (lbs)
5.2 (11.4)
4.6 (10.1)
4.0 (8.8)
3.4 (7.5)

Standard for all models:
In-depth illumination >0.9 (according to British Standard 4533 Section 103.2 1986)
Average lifetime of bulbs at max. voltage 22.8V: 1000 hours
Each light head is equipped with 2 O-rings as a water - and dust tight seal
Bulbs: special; Halogen/Xenon bulbs 50 watt, 22.8V with integrated dichroic (cool light) reflector
(1SIFF: Halogen/Xenon bulbs 25 watt, 13.8V with integrated dichroic (cool light) reflector
Each light head is equipped with 2 lenses, an interferencial and a colour correction filter
Ceiling support tube diameter 50 - 90 mm to optimise the laminar-flow surface

(right to change specifications reserved)
 
 
Non focusable surgical lights

criteria / model 2SIFF 1SIFF
Illumination intensity at 1 metre in lux ~ 50,000 ~ 25,000 (0.8m)
Field size at 1 metre in cm (inches) 20 (7.8) 20 (7.8)
Colour temperature (K) ~ 4,300K
+ or - 300K
~ 4,300K
+ or - 300K
Working distance in cm (inches) 70 - 120
(27 - 47)
70 - 120
(27 - 47)
Colour rendering index 93 93
Focal length in cm (inches) 60 (23.6) 60 (23.6)
Temperature increase in wound area at 100,000 lux and 1 metre in deg C (F) 10 (50) 10 (50)
Focus adjustable by sterilisable handle no no
Easy positioning by sterilisable handle yes yes
Dimmer with continuos light regulation yes yes
Support cardanic no
Number of light heads and bulbs for each model 2 1
Electric power (Watt) 100 25
Line voltage 22.8 13.8
Diameter of one beam in cm (inches) 8 (3.1) 8 (3.1)
Diameter of light heads circle in cm (inches)
(External-diameter of the surgical light)
28 (11) 8 (3.1)
Flow obstructing surface in cm2 130 50
Laminar-flow index (Leenemann) 7.4 5.2
Weight in Kg (lbs) 2.4 (5.4) 0.8 (1.8)
 
 
Worldwide references

We deliver ADMECO-Lux surgical lights to satisfied customers all over the world

Switzerland    

Kreisspital Freiamt Muri
Klinik Permanance Bern
Lindenhof Spital Bern
Ars Medica Clinic Gravesano
Hopital Cantonal Fribourg

GZO Spital Wetzikon
3 x 5SI/5SI
2 x 5SI/5SI
1 x 6SI/6SI
2 x 6SI/6SI
2 x 6SI/6SI
11 x 2SIFF-D
4 x 6SI/6SI/5SI
7 x 2SIFF-D
6 x 2SIFF-D

1 x 6SI mobile

2 x 4SI
2 x 3SIFF/3SIFF
1 x 5SI/5SI
2 x 3SI-D

Germany    
St. Josef Krankenhaus Moers
Universitatklinik Freiburg
Klinik Fleetinsel Hamburg
Stadt. Kliniken Frankfurt
Marienhospital Steinfurt
Ev. Krankenhaus Seelow
2 x 6SI/3SI
4 x 6SI/5SI
1 x 5SI/5SIC
5 x 4SI/4SI/4SI
3 x 6SI/6SI
2 x 6SI/4SI
1 x 6SI/6SI




1 x 2SIFF

Italy    

Tor Vergata Roma
Luigi Palazzolo Bergamo
Casa di Cura Columbus Roma
Ospedale Le Torrette Ancona
Casa di Cura Regina Albano
Ospedale Fl. del Ponte Varese
6 x 6SI/6SI
1 x 6SI/5SI-D
2 x 6SI/6SI
14 x 6SI/5SI
4 x 6SI/5SI
2 x 6S/6SI



4 x 6SI/6SI/5SI

6 x 6SI

Scandinavia    

Hospital Ringkobing
Kobenhavens Sygehus Herlev
Landssygehuset Torshavn
Private Hospital Trondhiem
Middlefart Hospital
Ortopediska Huset Stockholm
1 x 6SI/5SI
2 x 6SI/6SI
5 x 6SI/5SI
1 x 6SI/5SI
1 x 6SI/5SI
1 x 5SI/5SI/5SI


2 x 4SI/4SI

Russia    
St. Pertersburg
Niznevartovsk Hospital
Surgut Hospital
Hospital Novosibirsk
Zentral Bank Klinik Moskau
3 x 6SI/3SI
4 x 6SI/3SI
8 x 6SI/3SI
12 x 5SI/3SI
1 x 6SI/3SI


© Copyright EDL Lighting Industries | Designed and Maintained by NTH Internet Services