Surgical Lighting
| For major and minor surgery and as an examination lamp in: |
|
| • |
Operating rooms |
| • |
Out-/Inpatients |
| • |
Emergency Wards |
| • |
Examination rooms |
| • |
Veterinary practices |
| Versatile and compact design |
| • |
Air stream optimised for laminar-flow compatibility |
| • |
Light and flexible for easy positioning |
| • |
Removable, sterilsable handles |
| • |
Easy replacement of Halogen/Xenon bulbs |
| • |
Uniform illumination across working area |
| • |
Colour correction for visual comfort |
| • |
Shadow-free in operation field |
| • |
Very sturdy construction |
| • |
Hermetically sealed |
| High performance |
| • |
High lux output/intensity |
| • |
Deep cavity penetration |
| • |
Sharply focused, high intensity light pattern |
| • |
Heat reflected upwards and transmitted through the IR-transmitter |
| • |
Dimmable lights |
| • |
High lux up to 4 x 150,000 lux |
|

click picture to enlarge |
| |
 |
| |
| The comprehensive Admeco-Lux program |
|
| Ceiling |
| • |
Individual lights 2 beams 1-branch, “SOLO”, not focusable |
| • |
Individual lights 3-6 beams, 1-branch, “SOLO”, focusable |
| • |
Ceiling hanging surgical lights, 2-branches “DUO”, focusable |
| • |
Ceiling hanging surgical lights max 4-branches “MULTI” focusable |
| Wall |
| • |
Individual lights 2 beams, not focusable |
| • |
Individual lights 3-6 beams, focusable |
| Mobile |
| • |
Individual lights 1-2 beams, not focusable |
| • |
Individual lights 3-5 beams, focusable |
| • |
Optional with emergency power supply (as in picture) |
|

click pictures to enlarge

click pictures to enlarge

|
| |
 |
| |
| IR-Transmitter |
| Because of the infrared permable hood of the lamp most of the heat is exhausted upwards. The result is a cooler working field for the surgeons. |
| Diameter |
| The Admeco-Lux is specially designed for laminar-flow outlets. The very small diameter of only 8 cm and the stream optimised shape of the light heads are disturbing the airflow to a minimum. |
| Focus- / Positioning |
| The lamp can be positioneAd and focused fast and easily with the swivelling sterilisable handle. |
| Easily maneuverable with two centre-close joints |
| The rotation points A and B of the Admeco-Lux OT-lights are close to the centre. This creates an extreme mobility almost comparable with a ball-joint. With fingertip light manipulation Admeco-Lux lamps can be positioned in the appropriate angle. |
|

click pictures to enlarge

click pictures to enlarge

|
|
Enlightening Design |
 |
• Innovative
• High Quality
• High Performance
|
|
| |
Airborne particle concentration control for a operating room
Authors: Air & Climate Group, Dr Dipl.-lng. ETH Alfred Moser, Dr Yunlong Liu, ETH Zurich |
|
“The standard case is from a real situation except that persons around the table are represented by dummies. The 6-lamp light and the big light are placed in the same position, the big light is a dish-shaped light with a diameter of about 0.9m (CFD*1), the
6-lamp light is made up of 6 0.08m-diameter small lamps (CFD*2)” |
| “The large lamp will disturb the flow field so much that the particle concentration above the table is seriously affected CFD 1 shows the airflow vectors in the centre of the table. It is obvious that this large lamp is not suitable to be placed between air supply inlet and the operating table |
|
| |
 |
| |
| Surgical Light with colour video system |
|
| The system includes? |
Colour video camera integrated into a casing which can be attached to an Admeco-Lux surgical light or a separate arm (Admeco-Lux models 3SI, 4SI and 5SI).
Control unit includes interference filter |
| Colour video camera |
The colour video system designed to accompany the ADMECO-Lux surgical lights needs no additional , visible cables.
The system is optically integrated into the light design. The video camera is built into a casing which is then fastened to the Admeco-Lux surgical light or to an independent arm.
By means of the sterisable handle, the camera can be turned within the casing and the image positioned corrected as necessary
The system is simple to install and easy to maintain. |
| Control unit including interference filter |
The control unit of the colour video camera allows you to adjust the iris, zoom, focus
and white balance.
A green LED by the auto-iris, auto-focus or white balance buttons lights up when the function is activated. |
|
| |
|
Colour video system technical data |
| Camera |
1/4” CCD-Chip. Sony (10x zoom) |
| Scanning rate |
2:1 |
| Pixel |
752 (H) x 582 (V) |
| Horizontal frequency |
15652 Hz |
| Image frequency |
50 Hz |
| Auto shutter |
1/3 - 1/10,000 s; 20 steps |
| Minimum light |
4 lux |
| Fuse (electronic) |
400mAT (230V) |
| Focusing range zoom lens |
4.2 to 42mm |
| White balance |
Automatic |
| Fitting |
in a casing suitable for the ADMECOLux surgical light |
Control unit technical data |
TV standard
|
PAL (alternatively NTSC) |
| Resolution |
>460 (H) TV Lines x > 400 (V);
TV Lines |
| Signal output |
FBAS, Y/C (S-VHS, Hi8) |
| Video output |
Yes |
| Power supply |
230V, 50-60 Hz |
| Humidity |
<90% rF |
| Ambient temperature |
0 deg C to +50 deg C |
(Right to change specifications reserved) |

click pictures to enlarge

|
| |
 |
| |

| criteria / model |
6SI |
5SI |
4SI |
3SI |
| Illumination intensity at 1 metre in lux |
= 150,000 |
= 125,000 |
= 100,000 |
= 75,000 |
| Field size at 1 metre in cm (inches) |
18 - 27
(7.1 - 10.6) |
18 - 27
(7.1 - 10.6) |
18 - 27
(7.1 - 10.6) |
18 - 27
(7.1 - 10.6) |
| Colour temperature (K) |
~4,300K
+ or - 300K |
~4,300K
+ or - 300K |
~ 4300K
+ or - 300K |
~4300K
+ or - 300K |
| Working distance in cm (inches) |
70 - 200
(27 - 79) |
70 - 200
(27 - 79) |
70 - 200
(27 - 79) |
70 - 200
(27 - 79) |
| Colour rendering index |
93 |
93 |
93 |
93 |
| Focal length in cm (inches) |
60 (23.6) |
60 (23.6) |
60 (23.6) |
60 (23.6) |
| Temperature increase in wound area at 100,000 lux and 1 metre in deg C (F) |
10 (50) |
10 (50) |
10 (50) |
10 (50) |
| Focus adjustable by sterilisable handle |
Yes |
Yes |
Yes |
Yes |
| Easy positioning by sterilisable handle |
Yes |
Yes |
Yes |
Yes |
| Dimmer with continuos light regulation |
Yes |
Yes |
Yes |
Yes |
| Support |
cardanic |
cardanic |
cardanic |
cardanic |
| Number of light heads and bulbs for each model |
6 |
5 |
4 |
3 |
| Electric power (Watt) |
300 |
250 |
200 |
150 |
| Diameter of one beam in cm (inches) |
8 (3.1) |
8 (3.1) |
8 (3.1) |
8 (3.1) |
Diameter of light heads circle in cm (inches)
(External-diameter of the surgical light) |
40 (15.7) |
40 (15.7) |
39 (15.4) |
39 (15.4) |
| Flow obstructing surface in cm2 |
380 |
330 |
280 |
230 |
| Laminar-flow index (Leenemann) |
5.2 |
4.6 |
4 |
3.4 (7.5) |
| Weight in Kg (lbs) |
5.2 (11.4) |
4.6 (10.1) |
4.0 (8.8) |
3.4 (7.5) |
| Standard for all models: |
In-depth illumination >0.9 (according to British Standard 4533 Section 103.2 1986)
Average lifetime of bulbs at max. voltage 22.8V: 1000 hours
Each light head is equipped with 2 O-rings as a water - and dust tight seal
Bulbs: special; Halogen/Xenon bulbs 50 watt, 22.8V with integrated dichroic (cool light) reflector
(1SIFF: Halogen/Xenon bulbs 25 watt, 13.8V with integrated dichroic (cool light) reflector
Each light head is equipped with 2 lenses, an interferencial and a colour correction filter
Ceiling support tube diameter 50 - 90 mm to optimise the laminar-flow surface
(right to change specifications reserved) |
|
| |
 |
| |
| Non focusable surgical lights |
|

| criteria / model |
2SIFF |
1SIFF |
| Illumination intensity at 1 metre in lux |
~ 50,000 |
~ 25,000 (0.8m) |
| Field size at 1 metre in cm (inches) |
20 (7.8) |
20 (7.8) |
| Colour temperature (K) |
~ 4,300K
+ or - 300K |
~ 4,300K
+ or - 300K |
| Working distance in cm (inches) |
70 - 120
(27 - 47) |
70 - 120
(27 - 47) |
| Colour rendering index |
93 |
93 |
| Focal length in cm (inches) |
60 (23.6) |
60 (23.6) |
| Temperature increase in wound area at 100,000 lux and 1 metre in deg C (F) |
10 (50) |
10 (50) |
| Focus adjustable by sterilisable handle |
no |
no |
| Easy positioning by sterilisable handle |
yes |
yes |
| Dimmer with continuos light regulation |
yes |
yes |
| Support |
cardanic |
no |
| Number of light heads and bulbs for each model |
2 |
1 |
| Electric power (Watt) |
100 |
25 |
| Line voltage |
22.8 |
13.8 |
| Diameter of one beam in cm (inches) |
8 (3.1) |
8 (3.1) |
Diameter of light heads circle in cm (inches)
(External-diameter of the surgical light) |
28 (11) |
8 (3.1) |
| Flow obstructing surface in cm2 |
130 |
50 |
| Laminar-flow index (Leenemann) |
7.4 |
5.2 |
| Weight in Kg (lbs) |
2.4 (5.4) |
0.8 (1.8) |
|
| |
 |
| |
We deliver ADMECO-Lux surgical lights to satisfied customers all over the world
| Switzerland |
|
|
|
Kreisspital Freiamt Muri
Klinik Permanance Bern
Lindenhof Spital Bern
Ars Medica Clinic Gravesano
Hopital Cantonal Fribourg
GZO Spital Wetzikon |
3 x 5SI/5SI
2 x 5SI/5SI
1 x 6SI/6SI
2 x 6SI/6SI
2 x 6SI/6SI
11 x 2SIFF-D
4 x 6SI/6SI/5SI
7 x 2SIFF-D |
6 x 2SIFF-D
1 x 6SI mobile
2 x 4SI
2 x 3SIFF/3SIFF
1 x 5SI/5SI
2 x 3SI-D |
| Germany |
|
|
|
St. Josef Krankenhaus Moers
Universitatklinik Freiburg
Klinik Fleetinsel Hamburg
Stadt. Kliniken Frankfurt
Marienhospital Steinfurt
Ev. Krankenhaus Seelow |
2 x 6SI/3SI
4 x 6SI/5SI
1 x 5SI/5SIC
5 x 4SI/4SI/4SI
3 x 6SI/6SI
2 x 6SI/4SI |
1 x 6SI/6SI
1 x 2SIFF |
| Italy |
|
|
|
Tor Vergata Roma
Luigi Palazzolo Bergamo
Casa di Cura Columbus Roma
Ospedale Le Torrette Ancona
Casa di Cura Regina Albano
Ospedale Fl. del Ponte Varese |
6 x 6SI/6SI
1 x 6SI/5SI-D
2 x 6SI/6SI
14 x 6SI/5SI
4 x 6SI/5SI
2 x 6S/6SI |
4 x 6SI/6SI/5SI
6 x 6SI |
| Scandinavia |
|
|
|
Hospital Ringkobing
Kobenhavens Sygehus Herlev
Landssygehuset Torshavn
Private Hospital Trondhiem
Middlefart Hospital
Ortopediska Huset Stockholm |
1 x 6SI/5SI
2 x 6SI/6SI
5 x 6SI/5SI
1 x 6SI/5SI
1 x 6SI/5SI
1 x 5SI/5SI/5SI |
2 x 4SI/4SI |
| Russia |
|
|
|
St. Pertersburg
Niznevartovsk Hospital
Surgut Hospital
Hospital Novosibirsk
Zentral Bank Klinik Moskau |
3 x 6SI/3SI
4 x 6SI/3SI
8 x 6SI/3SI
12 x 5SI/3SI
1 x 6SI/3SI |
|
|
|
|